ACD GENie Calibration Gas System

ACD GENie calibration gas instruments
Calibration Gas System

 

GENie O3 ozone calibration gas GENie EC hydrogen calibration gas GENie QC-1 ammonia calibration gas Cl2 chlorine ClO2 chloring dioxide H2S hydrogen sulfide HCN hydrogen cyanide

Ozone, Hydrogen, Ammonia, Chlorine, Chlorine Dioxide, Hydrogen Sulfide & Hydrogen Cyanide

Compact, hand-held, accurate, economical and rugged, this family of integrateable and expandable calibration gas instruments will generate a variety of gases from one modular instrument. As your calibration gas needs grow, so does the GENie, with integrated, expandable modules that provide for a cost effective solution.

How does the GENie Calibration Gas System work? Learn more!

Download the GENie Calibration Gas System Brochure

Download our full Product Catalog

Hydrogen (H)
(PPM is variable with flow rate,
output given at 0.5 lpm)
0.5 - 50 or50 - 500 PPM
Chlorine .05 - 5 or 0.5 - 50 PPM
Chlorine Dioxide 0.5 - 5 PPM
Hydrogen Sulfide .05 - 15or.5 - 50 PPM
Hydrogen Cyanide .05 - 5 or.5 - 50 PPM
Air flow rate (with internal pump) 0.2 to 1 LPM
Sample draw rate
(with pump disabled)
0.1 to 1.2 LPM
Source life 10, 50, 100 hours
Warm-up time (to 90%) Approx. 2 minutes
L x W x H 5"W x 3.88"H x 3.13"D
Weight 2 lb. (907 g)
Operating temperature 0°C to 50°C
Relative humidity (intermittent use) 0 -100%
Accuracy ± 5% or ± 10%
Repeatability +/-5%
Battery power 4 Alkaline AA
Battery life 100 hours
GENie EC Calibration Gas Instrument

GENie EC Calibration Gas Instrument
(750-0200-01)

GENie EC hydrogen calibration gas Cl2 chlorine ClO2 chloring dioxide H2S hydrogen sulfide HCN hydrogen cyanide
Hydrogen, Chlorine, Chlorine Dioxide, Hydrogen Sulfide & Hydrogen Cyanide

This instrument has been specifically tailored to fit the high PPM range of hydrogen detectors. The GENie EC output can be adjusted down in order to accommodate the calibration of the low level leak checking instrumentation currently on the market.

  • Adjustable hydrogen calibration gas concentrations created on demand
  • Interchangeable generating sources
  • Expandable concentrations and gases
  • Integrated microprocessor controlled feedback
  • Non-hazardous transport
  • Ideal for demand flow or diffusion applications
  • English, French, German and Spanish user interfaces are available

Download the GENie EC brochure

Ozone (O3) adjustable 0.2 to 1.0 PPM
Air flow rate 0.2 @ 1.0PPM - 1.0 @ 0.2 PPM
Source life 500 hours
Warm-up time (to 90%) Approx. 2 minutes
L x W x H 5"W x 3.88"H x 3.13"D
Weight 2 lb. (907 g)
Operating temperature 0°C to 50°C
Relative Humidity (intermittent use) 0 -100%
Accuracy +/-10%
Repeatability +/-5%
Battery power 4 Alkaline AA
Battery life 6 hours
GENie O3 Calibration Gas Instrument

GENie O3 Ozone Calibration Gas Instrument
(750-0200-02)

GENie O3 ozone calibration gas Ozone

The GENie O3 is the latest in our line of portable calibration gas standards. Small, lightweight and operating on four AA batteries, the GENie O3 can be utilized in its fanny pack by a technician climbing around equipment to calibrate the most difficult to reach ozone sensors. Plugged in to mains power, the instrument can calibrate hand held detectors right at your service bench.

  • Most accurate source of ozone calibration gas on the market
  • Selectable concentrations
  • Integrated microprocessor controlled feedback
  • Compact, portable handheld design
  • Long Life
  • Simple to use
  • English, French, German and Spanish user interfaces are available
Download the GENie O3 brochure
Ammonia (NH3) 10 to 500 or 20 to 1000PPM
Air Flow Rate (with internal pump) Variable
Source life 8 hours / vial
Warm-up time (to 90%) < 30 seconds
L x W x H 5"W x 3.88"H x 3.13"D
Weight 2 lb. (907 g)
Operating Temperature 0°C to 50°C
Relative Humidity (intermittent use) 0 -100%
Accuracy +/-10%
Repeatability +/-5%
Battery Power 4 Alkaline AA
Battery Life Approx. 5 hours
GENie QC-1 Calibration Gas Instrument

GENie QC-1 Ammonia Calibration Gas Instrument
(750-0200-03)

GENie QC-1 ammonia calibration gas Ammonia

The GENie QC-1 is our newest gas instrument for ammonia calibration gas. By utilizing a sealed glass ampule that is broken for use, the GENie QC-1 is the perfect tool for anyone calibrating fixed or portable ammonia sensors. With user adjustable outputs, the GENie QC-1 can be set to a wide range of outputs allowing for calibration of nearly any ammonia detector on the market.

  • 96 hours of source gas include
  • Disposable gas vials have no shelf life
  • Most accurate source of NH3 calibration gas on the market
  • Integrated microprocessor controlled feedback
  • Non-hazardous transport
  • Simple to use, NIST traceable
  • English, French, German and Spanish user interfaces are available
Download the GENie QC-1 brochure